53 COREX installations
on the globe.
Every Speed-o-Clar® / COREX plant in the released installation set is a selectable point. Click for location and plant details. Coordinates are currently city-level approximations.
Global presence.
Drag, zoom a country, select a point — plant and site in the panel.
Click and drag to rotate
| Region | Plant type | Plants | Years in set | Publication status |
|---|---|---|---|---|
| France | Municipal + industry | 51 | 2010–2024 | On globe · city coords |
| Chile | Municipal (Parral) | 2 | 2023 | On globe · detail follows |
| Germany | — | 0 | planned 2026/27 | VÆLARUM site |
Globe total: 53. Further Densiline references and imagery are outside this released set and appear after rights clearance.
Chile · Parral
Parral 1 · COREX / Speed-o-Clar®
Municipal installation in the released set. Module ø 16 m. Client per list: DSLN SA Chili. Operating metrics and imagery after clearance; selectable on the globe (city coordinates).
- Module ø
- 16 m
- Year
- 2023
- Product
- COREX
- Coords
- City
Parral 2 · COREX / Speed-o-Clar®
Second Parral unit the same year, module ø 16 m. Linked on the globe and directory like Parral 1. No performance claims without released measurements.
- Module ø
- 16 m
- Year
- 2023
- Product
- COREX
- Coords
- City
France · image and brand rights
The released set includes 51 plants in France as globe points (city coordinates, 2010–2024). Detailed case studies, names and photos will appear stepwise after written brand and image agreements — not as an unsecured “60+” marketing figure.
Operating data (selection)
From the Densiline reference pack (updated 29 Jan 2026). No cleared FR press photos here — operational facts only. Globe remains the released 53-plant set.
Surface overflow rate
Calculated Va repeatedly > 1 m/h without sludge washout. One washout logged 16 Jan 2023 at Va > 1.2 m/h.
Recirculation & peaks
Recirculation 50% instead of 200%. Storm peaks 1,811 and 1,366 m³/d vs prior ~800 m³/d. FeCl₃ pumps on trial stop.
Overflows before/after
St-Coulomb events/year 57→5; Lanvollon 65→0; St-Méloir 87→16 (agency data).
Municipal & industry
Quettreville (SAUR, ø 13 m): shallow 1.80 m side wall. Fibre Excellence ø 52 m, second unit 2018; sludge-start test 2,400 m³/h (Va 1.13 m/h).
Source: Densiline — reference update 29/01/2026.
CO₂ context
Independent LCA (VERACITY / Densiline, 2025), 100,000 PE plant, Level 1 France: 4,375 t CO₂e avoided over 20 years. Detail: Technology · CO₂ balance.
Request a plant assessment